APC SMART UPS -SURT20KRMRXLI (20KVA) 3 PHASE

77,542.00

UVTP20KHS Features

Key Features

Run time for loadW

Max. Capacity Used

100%
Output power capacity

16.0kWatts / 20.0kVA
Nominal Output Voltage

400V 3PH
Nominal Input Voltage

400V 3PH
Input Connections

Hard Wire 5-wire (3PH + N + G)
Maximum Input Current

27.0A
APC Smart-UPS VT 20kVA 400V, w/Start-Up 5X8, Internal Maintenance Bypass, & Parallel Capability
UPS is supplied without batteries. 3rd party battery system must be purchased separately.
Includes: CD with software, Installation guide, Network Management Card, Power modules ship installed, User Manual
  • Parallel-capacity capable
    Increases total power capacity by using multiple uninterruptible power supplies simultaneously.
  • Parallel-redundant capable
    Power the connected equipment with multiple uninterruptible power supplies to increase system redundancy

Smart-UPS VT Features & Benefits

Protection

Safety-agency approved

Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Frequency and voltage regulation

Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Cold-start capable

Provides temporary battery power when the utility power is out.

Marketing Features

Hot-swappable batteries

Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

Sustainability

EU CoC for UPS

Ensures that UPSs sold in the EU are highly efficient

Manageability

SmartSlot

Customize UPS capabilities with management cards.
InfraStruXure Manager Compatible

Enables centralized management via the APC InfraStruXure Manager.
Network manageable

Provides remote power management of the UPS over the network.
Audible alarms

Provides notification of changing utility power and UPS power conditions
LCD display

Alpha-Numeric Display which displays system parameters and alarms.
LED status indicators

Quickly understand unit and power status with visual indicators.
Programmable frequency

Ensures compatibility with different input frequencies.

Total Cost of Ownership

Input power factor correction

Minimizes installation costs by enabling the use of smaller generators and cabling.
Manual maintenance bypass

Reduces installation costs by eliminating the need for an external mechanical bypass.
Temperature-compensated battery charging

Prolongs battery life by regulating the charge voltage according to battery temperature.
Intelligent battery management

Maximizes battery performance, life, and reliability through intelligent, precision charging.

Availability

Generator compatible

Ensures clean, uninterrupted power to protected equipment when generator power is used.
Automatic internal bypass

Supplies utility power to the connected loads in the event of a UPS power overload or fault.
Dual mains input

Increases availability by allowing the UPS to be connected to two separate power sources.
Scalable runtime

Allows additional run time to be quickly added as needed.
Battery modules connected in parallel

Delivers higher availability through redundant batteries.

Serviceability

Automatic self-test

Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Shippable with modules installed

Enables pre-installation UPS staging and testing and faster installation.
Battery replacement without tools

Enables fast battery replacement, lowering Mean Time to Repair (MTTR).
Modular design

Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.
Technical Specifications

Output

Max Configurable Power (Watts)

16.0kWatts / 20.0kVA
Output Voltage Note

Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage
Output Voltage Distortion

Less than 5% at full load
Output Frequency (sync to mains)

47 – 53 Hz for 50 Hz nominal
Output Frequency (not synced)

50Hz +/- 0.1% for 50Hz nominal
Other Output Voltages

380, 415
Load Crest Factor

3 : 1
Topology

Double Conversion Online
Waveform type

Sine wave
Maximum Output Current

32
Bypass

Built-in Maintenance Bypass, Built-in Static Bypass

Input

Input frequency

47 – 70 Hz (auto sensing)
Input voltage range for main operations

304 – 477V
Other Input Voltages

380, 415
Input Power Factor at Full Load

0.98

Batteries & Runtime

Battery type

No internal battery – uses external battery system

Communications & Management

Interface Port(s)

DB-9 RS-232, SmartSlot
Pre-Installed SmartSlot™ Cards

Control panel

Multi-function LCD status and control console
Audible Alarm

Audible and visible alarms prioritized by severity
Emergency Power Off (EPO)

Yes

Physical

Maximum Height

823MM, 82.3CM
Maximum Width

352MM, 35.2CM
Maximum Depth

813MM, 81.3CM
Net Weight

134.0KG
Shipping weight

173.0KG
Shipping Height

1290MM, 129.0CM
Shipping Width

720MM, 72.0CM
Shipping Depth

1110MM, 111.0CM
Color

Black

Conformance

Approvals

C-tick, CE, EN 50091-2, EN 61000-3-2, EN 61000-3-3, EN/IEC 62040-3, ISO 14001, ISO 9001, RCM, VFI-SS-111

Related Products